Pharamaceutical Industry & Life Sciences
Area Cleaning Operation in Clean Room In Production pharama Industry:
Start cleaning of the area after the cleaning of the equipments.
Start the cleaning operation of ceiling and then to walls from top progressing to downwards.
Clean the door and window glasses using (Disinfectant solution) wet duster.
Clean the doors, door closures, handles and all the hinges of the door using dry followed by wet and again with dry duster.
If weighing balance is present in the processing room, clean it by using wet duster followed by dry duster.
Clean the pallets, trolleys, etc using a wet duster followed by a clean dry duster.
Remove the dust from the switchboards, utility pendants using the vacuum cleaner and wipe with clean dry duster.
Clean the SOP stand using clean dry duster.
Clean the accessories box using the wet duster followed by clean dry duster.
Clean the ceilings of Air Handling Unit (AHU) supply grilles with a pipe brush and vacuum cleaner during a product change over.
Clean and mop the entire floor twice using 1.0% disinfectant solution (Domex / Lysol) using Aluminum stick mop / Scrubber cum drier.
Clean the tube light fixtures using wet duster followed by a clean dry duster.
Clean the coving, corners of the entire area using wet (with disinfectant) duster.
Clean the walls of the entire area using (with disinfectant) wet mop.
Collect all the waste from the waste bin into a poly bag and send to the scrap room. Sanitize the waste bin with (Disinfectant solution) wet duster followed by dry duster.
Clean the drain parts and drain using 1% Disinfectant solution and 10% sodium Hypochloride solution once a week as per respective SOP scrubbing with scotch brite followed by sufficient quantity of water. Pour 0.5 liters of 1% disinfectant solution into the drain. Close the drain with drain trap, perforated plate and lid.
Enter the cleaning details in the ‘Primary Production area cleaning Record’ as per Type-B Cleaning:
Follow the for cleaning of Processing Room.
Collect all the waste from the waste bin into a poly bag and send to the scrap room. Clean the waste bin with a dry duster.
Clean and mop the entire floor twice using 1% disinfectant solution (Domex / Lysol.) using Aluminum stick mop / Scrubber cum dryer.
Enter the cleaning details in the ‘Primary Production area cleaning Record’ as per An
Type -C Cleaning:
Clean the door and window glasses using (Disinfectant solution) wet duster.
Clean the doors, door closures, handles and all the hinges of the doors using wet and dry duster.
Collect all the waste from the waste bin into a poly bag and send to the scrap room. Clean the waste bin with a dry duster.
Clean the SOP stand using clean dry duster.
Clean and mop the entire floor twice using 1% disinfectant solution (Domex / Lysol.) using Aluminum stick mop / Scrubber cum dryer.
Enter the cleaning details in the ‘Primary Production area cleaning Record’ as per Annexure No.-I
Production Corridor Area
Doors, door closures, handles window glasses, fire extinguishers, emergency lights, switchboards, coving, corners of the entire area cleaned daily.
Clean and mop the entire floor twice a day.
Tube light fixture, walls, ceiling and corner angle cleaned once a week.
Clean the door and window glasses using (Disinfectant solution) wet duster.
Clean the doors, door closures, handles and all the hinges of the doors using wet and dry duster.
Clean the fire extinguishers, emergency lights using dry duster.
Clean the switchboards using dry duster.
Clean the coving, corners of the entire area using wet (with disinfectant) duster.
Clean the ceiling, walls and corner angles using wet duster followed by dry duster. (Once a week).
Clean the tube lights fixtures using dry duster (Once a week).
Clean and mop the entire floor twice using 1% disinfectant solution (Domex / Lysol) using Scrubber cum dryer / Aluminum stick mop at the start and at the end of the shift or as and when required.
Enter the cleaning details in the ‘Semi Finish Product Storage Area, Production Corridor Area and Equipment Wash Area Cleaning Record’ as per Annexure No.-II
Equipment wash area
Door, door closures, handles window glasses, emergency lights, switchboards, coving, corners and drain point of the entire area cleaned daily.
Clean and mop the entire floor twice a day.
Tube light fixture cleaned once a week.
Clean the door, window glasses, handles and all the hinges of the doors using (Disinfectant solution) wet duster.
Clean the table using (Disinfectant solution) wet duster followed by dry duster.
Clean the tube lights fixtures using dry duster (Once a week).
Clean the switchboards, utility pendants using clean dry duster.
Collect all the waste from the waste bin into a poly bag and send to the scrap room.
Clean the waste bin using wet duster followed by dry duster.
Clean the SOP stand using clean dry duster.
Cleaning of covings, corners and walls of the entire area using (Disinfectant) wet duster Clean and mop the entire floor twice using 1% disinfectant solution (Domex / Lysol) using Aluminum stick mop .
At the end of the working shift, clean the drain parts and Pour of 10% Hypochloride solution into the drain. Scrubbing with scotch brite followed by sufficient quantity of water. Close the drain with drain trap, perforated plate and lid.
Enter the cleaning details in the ‘Semi Finish Product Storage Area, Production Corridor Area and Equipment Wash Area Cleaning Record’ as per Annexure No.-II.
Semi finish Product storage area and other areas:
Semi finish product storage area include semi finish quarantine-I & II, Granules quarantine I & II and other areas are days packing store, Genitor room, scrap.room and tool rooms.
Door, door closures, handles window glasses, emergency lights, switchboards, SS containers, coving, corners and drain point of the entire area cleaned daily.
Tube light fixture, walls, ceiling and corner angle cleaned once a week.
Clean and mop the entire floor twice a day.
Clean the door, window glasses, handles and all the hinges of the doors using (Disinfectant solution) wet duster.
Clean the table using (Disinfectant solution) wet duster followed by dry duster.
Clean the switchboards, utility pendants using clean dry duster.
Clean the pallets, trolleys, SS containers, In-process Containers etc using a clean dry duster.
Clean the coving, corners of the entire area using wet (with Disinfectant) duster.
If the weight balance is present in Semi finish Product storage area clean it using wet duster followed by dry duster.
Clean the ceiling, walls and corner angles using wet duster followed by dry duster.(once a week)
Clean the tube lights fixtures using wet duster followed by dry duster.( once a week)
Clean and mop the entire floor using 1% disinfectant solution(Domex / Lysol) using scrubber cum dryer / Aluminium stick mop at the start and at the end of shift or as and when required.
Enter the cleaning details in the ‘Semi Finish Product Storage Areas, Production Corridor Area and Equipment Wash Area Cleaning Record’ as per Annexure No. -II
Forms and Records (Annexures)
- Processing room cleaning record
- Semi Finish Product Storage Areas, change part room , Production Corridors Area And Equipment Wash Area Cleaning Record